TEK Power Energy Solutions

TEK Power Energy Solutions offer consulting solutions for effective usage of power. We offer effective and efficient services such as power Quality Audit, Harmonic Mitigation, power Quality Improvement, Lead – Lag PF compensation, etc.

Power Quality Audit

Power Quality Audits Identifies Power Quality issues. This will further help you to address reliability and stability concerns before they actually impact on your facilities performance and more important on bottom line of organization.

Benefits of Power Quality Analysis

  • Assist in preventative and predictive maintenance
  • Identify source and frequency of events
  • Establish precise location and timing of events
  • Develop maintenance schedules
  • Monitor and trend conditions
  • Ensure equipment performance
  • Assess sensitivity of process equipment to disturbances
  • Evaluate performance against specifications
  • Analyze harmonics, Flicker, Transients frequency variation, voltage variations (sag & swell.)

Major Covered Parameters

  • Active, reactive and apparent power per phase and their aggregate
  • Active, reactive energy – consumed and produced (export / import)
  • Peak Voltage and current, Frequency
  • Harmonics for voltage, current up to the 50th order
  • Flicker measurements
  • Power factor
  • Displacement factor and Tangent
  • Neutral current
  • Crest Factor for V and I
  • K factor for currents
  • V and I unbalance in %
  • Total Harmonic Distortion Factor
  • Inrush capture
  • Transients Recording

Harmonic Mitigation

Harmonic mitigation is taking action to minimise the presence of harmonics in your electrical system and can achieve great cost savings. harmonics are extra frequencies that when present in an electrical circuit, which distort the AC sine wave. Harmonics are very harmful within an electrical system and can have serious consequences.

For example, the presence of harmonics reduces the life of equipment. It is possible that the investment that you made in your motors & drives will not be realised if they are damaged and need replacing before their expected life span. This can be very expensive. With a dedicated team we conduct complete harmonics study to analyse the cause of the harmonics & eliminate with high level Active filters proven to improve the efficiency of the systems.

Drives Harmonic Mitigation

The drives connected in the power system results in a combination of non-linear and linear systems making the system complicated. Drives operate with semicondutor switching operates at a certain switching frequency generating harmonics, voltage niotches & distortions.

TEK Power active filters have performed exceptionally with the problems of DC drives & other drive harmonics. Methods to mitigate harmonics involve using passive technology by using a reactor or complete active filter technology. These harmonic filters can be specifically connected to the drive to mitigate the harmonics.

Power Factor Improvement Solution

Power Factor indicates how efficiently electric power is used in a system. Due to inductive loads, operation of dynamic loads, low loads & imbalance in power systems the PF is adversly affected, leading to utilities imposing penalties. The improvement PF is not only for cutting down energy costs but to use energy efficiently & reduce bad environmental effects. We offer complete PF correction services for your power systems using wide range of technology with complete site inspection, to suit your needs ranging from APFCs, RTPFCs, Active Filters & Smart Hybrid solutions.

KVAH Billing Reduction

KVAh billing is incorporated to ensure that customers use power efficiently with reduced losses .The reactive power is drawn from the grid as per the process of load operation and type of loads like drives, motors, non-linear & inductive loads, which leads to additional billing charges. These charges can be eliminated by installing reactive power compensators like Active filter , SHAF solution , RTPFCs etc . These solutions maintain unity PF by reducing the KVAh units consumed r as per the load demand using cutting edge technology , so the customer after installation will exempted from paying additional charges for the KVAh units consumed.

Unbalance Compensation

Unbalance occurs in the power systems when the voltages and currents in the three phases are unequal, this is due to the unequal load distribution in the electrical network. These causes degradation of equipments, cable derating, inefficient operation, tripping of equipement, fluctuating torques in the motors etc.., TEK Power has provided special solution to tackle L-L unbalance & negative sequence where the specifically designed controller to measure the components of each line and counteract the unbalance. If you have problems with unbalance hindering the processes & production.